店鋪基本資料信息
|
|||||||||||||||||||||||||

Explosion proof enclosure rated Class I Division 1 Groups B-D, Ex d IIB+H2, AEx d IIB+H2
Intrinsically Safe Rated Class I, Div 1, Groups A-G, Ex ia IIC, AEx ia IIC
Non-Incendive Class I Div 2 A-D, Ex nA
SIL 2
Local status LED's
Local DIP Switches/Calibration Buttons
Auto Tuning with dynamic gain selection
Utilizes HART 5
Simple calibration via local interface
| Selection Code | Example | ||
| 3 | 3 | ||
| Protocol | HART | 2 | 2 |
| Diagnostics | Standard | 0 | 1 |
| Advanced (with pressure sensing) | 1 | ||
| Pro (with sensing and full ValveSight dianostics) | 2 | ||
| Material | Aluminum, White Paint (Valtek) | 0 | 0 |
| Stainless Steel, No Paint (Valtek) | 1 | ||
| Aluminum, Black Paint (Automax) | 2 | ||
| Aluminum, Food-Grade White Paint (Automax) | 3 | ||
| Aluminum, Black Paint (Accord) | 4 | ||
| Aluminum, Food-Grade White Paint (Accord) | 5 | ||
| Design Version | MD | MD | |
| Certifications | FM/CSA |
-1 | -10 |
| FM/CSA |
-2 | ||
| INMETRO Ex ia IIC Ga T4/T5; Ex ia IIIC T95C Da; Ex d IIB+H2 T5 Gb (South America) | -6 | ||
| ATEX |
-7 | ||
| North American |
-10 | ||
| General Purpose | -14 | ||
| ATEX |
-15 | ||
| IECEx |
-16 | ||
| IECEx |
-21 | ||
| ATEX: Mylar Multiple Concept Label: | -28 | ||
| Explosion Proof: Ex d IIB+H2 Ex td A21 IP65 T95°C Intrinsically Safe: Ex ia IIC, T4: Ex iaD 20 T950C | |||
| Nonincendive: II 3G Ex nL nA IIC, Ex tD A22 T950C | |||
| IECEx : Mylar Multiple Concept Label: | -33 | ||
| Explosion Proof: Ex d IIB+H2 T5; II 2D Ex tD A21 | |||
| Intrinsically Safe: Ex ia IIC T4, Ex iaD 20 T95°C | |||
| North America: Mylar Multiple Concept Label: | -34 | ||
| FM/CSA Explosion Proof, Intrinsically Safe, Non-Incendive | |||
| KOSHA Ex d IIB + H2 | 35 | ||
| Shaft | DD 316 Stainless Steel Shaft (Valtek Standard) | -D6 | -D6 |
| NAMUR 316 Stainless Steel (VDI/VDE 3845) | -N6 | ||
| Conduit Connections | ½" NPT | -E | -M |
| M20 | -M | ||
| Action | Four-way (Double-Acting) | -4 | -4V |
| Three-way (Single-Acting) | -3 | ||
| Three-way Purge (Single Acting) not for use with natural gas (used to purge spring side of actuator with instrument air) | -3P | ||
| Four-way Vented (Double-Acting) | -4V | ||
| Three-way Vented (Single-Acting) | -3V | ||
| Temperature | Low Temperature (-40°F to 176°F; -40°C to 80°C) | -40 | -40 |
| Gauges | SS with brass internals, psi (bar/kPa) (Valtek Standard) | -OG | -KS |
| SS with SS internals, psi (bar/kPa) | -OS | ||
| SS with brass internals, psi (kg/cm2 ) | -KG | ||
| SS with SS internals, psi (kg/cm2 ) KS | -KS | ||
| No Gauges | -U | ||
| Special Options | No special options | -OO | -OF |
| 4-20 mA Position Feedback | -OF | ||
| Remote Mount Feedback (Contact Mfg for Cert options) ** | -RM | ||
| 4-20 mA Position Feedback and Remote Mount Feedback (Contact Mfg for Cert options)** | -FR |
||
品類齊全
省心省力,一站購齊
一對一客服
選型詢價,快速響應
貨期保障
多倉直發,貨期無憂
正品貨源
正品保障,誠信服務